Calibrated to NEC Table 310.16 & ABYC E-11 Marine/RV DC Standards
VoltDropLab DC & Solar Engineering
Wire & Drop Calc Inverter Sizing Solar MPPT Voc LiFePO4 Runtime AWG Chart

1000W 12V Anchor Windlass Wire & 90A Breaker Calculator (Bow to Battery)

Equipment: 1000W 12V Boat Anchor Windlass (Lewmar Pro-Fish 1000 / Lofrans / Muir) • Typical Working Load: 85 Amps (Peak Stall: 130A) • Recommended Slow-Blow Breaker: 90A Thermal Breaker.

Pre-Loaded: 1000W 12V Boat Anchor Windlass (Lewmar Pro-Fish 1000 / Lofrans / Muir) (85A Working Load @ 20ft Bow/Chassis Run)

Real-time AWG sizing, thermal ampacity verification, SVG wiring diagram & shareable BOM generator

Volts
= 1,020 Watts
Amps
Watts

Tip: Type either Amps or Watts — both sync automatically.

Round-Trip Loop: 40 ft
Feet
Recommended Wire Size
1/0 AWG
53.5 mm² (8.25mm core) Drop Limited
Actual Voltage Drop
2.83% (-0.34V)
At Load: 11.66V Heat Loss: 28.9W
Required Fuse & Lugs
125A Fuse
MRBF (Terminal Fuse Block) or MEGA / ANL Fuse Lug Stud: 3/8" (M10)
Advertisement • CLS-Protected Slot (winch-1000w-12v-boat-anchor-windlass-wire-size)
Google AdSense / Header Bidding Unit Ready (Zero Layout Shift Container)

1000W 12V Boat Anchor Windlass Cable Gauge Chart (10ft to 35ft One-Way Run)

Because anchor windlasses and recovery winches sit at the extreme bow of the boat or rear bumper of the truck (20–35 feet from the battery), round-trip loop length reaches 40–70 feet:

One-Way Distance Round-Trip Loop Recommended Cable Gauge Voltage Drop @ 85A Dedicated Breaker Size
10 ft One-Way 20 ft Loop 4 AWG 3.69% (-0.44V) 90A Thermal Breaker
15 ft One-Way 30 ft Loop 2 AWG 3.48% (-0.42V) 90A Thermal Breaker
20 ft One-Way 40 ft Loop 2 AWG 4.64% (-0.56V) 90A Thermal Breaker
25 ft One-Way 50 ft Loop 1 AWG 4.6% (-0.55V) 90A Thermal Breaker
30 ft One-Way 60 ft Loop 1/0 AWG 4.38% (-0.53V) 90A Thermal Breaker
35 ft One-Way 70 ft Loop 2/0 AWG 4.06% (-0.49V) 90A Thermal Breaker

Compare Other Windlass, Bow Thruster & Winch Wire Guides