Calibrated to NEC Table 310.16 & ABYC E-11 Marine/RV DC Standards
VoltDropLab DC & Solar Engineering
Wire & Drop Calc Inverter Sizing Solar MPPT Voc LiFePO4 Runtime AWG Chart

Inverter Wire Size & Fuse Calculator (12V / 24V / 48V)

Pure sine wave inverters consume an extra 8% to 15% overhead due to DC-to-AC conversion inefficiency. Use our preset selector or interactive calculator below to size your cables and Class-T / ANL overcurrent protection.

Inverter Battery Cable & Fuse Sizing Engine (Default: 2000W @ 12V = 189.4A)

Real-time AWG sizing, thermal ampacity verification, SVG wiring diagram & shareable BOM generator

Volts
= 2,272.8 Watts
Amps
Watts

Tip: Type either Amps or Watts — both sync automatically.

Round-Trip Loop: 10 ft
Feet
Recommended Wire Size
2 AWG
33.6 mm² (6.54mm core) Drop Limited
Actual Voltage Drop
2.51% (-0.3V)
At Load: 11.7V Heat Loss: 57W
Required Fuse & Lugs
250A Fuse
Class-T Fuse (High AIC for LiFePO4) or ANL Fuse Lug Stud: 3/8" (M10)
Advertisement • CLS-Protected Slot (inverter-hub-middle)
Google AdSense / Header Bidding Unit Ready (Zero Layout Shift Container)

Master Inverter Cable & Fuse Reference Table (5-Foot One-Way Run)

Click any inverter configuration below to open its full distance chart and printable BOM sheet:

Inverter Model System Voltage Max Continuous Amps Recommended Cable (5ft) Main Fuse Size Detailed Spec Sheet
1000W Pure Sine 12V DC 94.7A 4 AWG 125A View 1000W 12V Chart →
1500W Pure Sine 12V DC 142A 4 AWG 200A View 1500W 12V Chart →
2000W Pure Sine 12V DC 189.4A 2 AWG 250A View 2000W 12V Chart →
3000W Pure Sine 12V DC 284.1A 1/0 AWG 400A View 3000W 12V Chart →
2000W Pure Sine 24V DC 92.6A 6 AWG 125A View 2000W 24V Chart →
3000W Pure Sine 24V DC 138.9A 4 AWG 175A View 3000W 24V Chart →
4000W Pure Sine 24V DC 185.2A 2 AWG 250A View 4000W 24V Chart →
3000W Pure Sine 48V DC 67.9A 8 AWG 100A View 3000W 48V Chart →
5000W Pure Sine 48V DC 113.2A 6 AWG 150A View 5000W 48V Chart →
8000W Pure Sine 48V DC 181.2A 2 AWG 250A View 8000W 48V Chart →